AirPAP
AirPAP is a single, refined device platform offered as seven models — from straightforward CPAP up to adaptive servo-ventilation. Every model shares the same 1.72 kg chassis, 4.3″ colour touchscreen and integrated humidifier; what changes is the therapy capability.
AirPAP treats sleep-disordered breathing by keeping the upper airway open during sleep. It is suitable for adults and children weighing more than 30 kg / 12 years, for home or clinical use.

CPAP & APAP devices
BiLevel devices
BiLevel
3–25 mbarTwo-pressure therapy (BiLevel S) for patients who need separate inspiratory and expiratory pressures.
AutoBiLevel
3–25 mbarAuto-adjusting BiLevel that titrates both pressure levels automatically, with the full CPAP/BiLevel S set.
BiLevel-ST
3–35 mbarAdds timed and spontaneous/timed BiLevel (T and ST) with a backup rate for patients needing ventilatory support.
BiLevel-VT
3–35 mbarVolume-targeted BiLevel (VT) for assured tidal volume, on top of the complete BiLevel mode set.
Therapy modes
Eight selectable modes — from fixed CPAP to adaptive servo-ventilation. Open any mode for its waveform, physiology and adjustable parameters.
Continuous Positive Airway Pressure
A single, constant pressure that keeps the upper airway open throughout the breath.
Learn more AUTOCPAPAutomatic Positive Airway Pressure
CPAP that titrates itself between a minimum and maximum as the night’s needs change.
Learn more BiLEVEL SBiLevel S (Spontaneous)
Two pressure levels — higher on inspiration, lower on expiration — fully patient-triggered.
Learn more BiLEVEL TBiLevel T (Timed)
Time-controlled two-level pressure delivered to a set rate and inspiratory time.
Learn more BiLEVEL STBiLevel ST (Spontaneous–Timed)
Supports spontaneous breaths and adds a timed backup breath when effort is missing.
Learn more BiLEVEL VTBiLevel VT (Volume-Targeted)
Bilevel support that adjusts inspiratory pressure to reach a target tidal volume.
Learn more AUTOBiLEVELAutoBiLevel (Auto-Adjusting)
Bilevel therapy that auto-titrates both pressure levels within set limits.
Learn more ASVAdaptive Servo-Ventilation
Adaptive bilevel therapy that adjusts pressure support breath-by-breath to stabilise ventilation.
Learn moreModel & mode matrix
Each model includes every mode of the models below it.
| Models | CPAP | AutoCPAP | BiLevel S | AutoBiLevel | BiLevel T | BiLevel ST | BiLevel VT | ASV |
|---|---|---|---|---|---|---|---|---|
| CPAP | ● | |||||||
| AutoCPAP | ● | ● | ||||||
| BiLevel | ● | ● | ● | |||||
| AutoBiLevel | ● | ● | ● | ● | ||||
| BiLevel-ST | ● | ● | ● | ● | ● | ● | ||
| BiLevel-VT | ● | ● | ● | ● | ● | ● | ● | |
| ASV | ● | ● | ● | ● | ● | ● | ● | ● |
Technical specifications
Shared specifications
- Dimensions
- 270 × 175 × 124 mm
- Weight
- 1.72 kg
- Display
- 4.3″ color touchscreen
- Processor
- 480 MHz
- Ramp
- 5–60 min
- Humidifier
- Integrated, heated
- Comfort
- RESFLEX pressure relief
- Data logging
- 365 days
- Sensing
- Digital pressure & flow